Laryngeal mask airway (LMA) ventilation is a method for
providing rescue ventilation to unconscious patients or patients without a gag
reflex that is technically easier than use of most other effective ventilatory
methods. It is used by anesthesiologists in many settings that previously
required endotracheal intubation.
The laryngeal mask airway (LMA) is a commonly used
supraglottic airway. The LMA is an orally introduced supraglottic airway tube
with a cuffed mask at one end that forms a low-pressure seal around the
laryngeal inlet. LMA ventilation has several advantages over other methods.
Unlike endotracheal tubes, LMAs can be successfully
inserted blindly and by inexperienced operators.
Unlike bag-valve-mask (BVM) ventilation, LMAs avoid the
difficulties of attaining and maintaining an adequate face-mask seal, they
bypass soft tissue obstruction of the upper airway, and they cause less gastric
insufflation than BVM ventilation.
Some available types of LMAs allow passage of an
endotracheal tube (intubating LMAs) or a gastric decompression tube. Some have
a fixed, anatomically correct shape that further optimizes ease of insertion.
Some newer mask designs replace the inflatable cuff with a gel–filled cuff that
molds to the airway.
LMAs, like the other supraglottic airways (eg, King laryngeal tube and esophageal-tracheal double lumen tube [Combitube]), are temporary airways that must, after several hours, be removed or be replaced by a definitive airway, such as an endotracheal tube or surgical airway (cricothyrotomy or tracheostomy).
Indications for Laryngeal Mask Airway
Apnea, severe respiratory failure, or impending
respiratory arrest in which endotracheal intubation cannot be accomplished
Certain elective anesthesia cases .
LMAs are useful in situations where bag-valve-mask ventilation is difficult:Patients with severe facial deformity (traumatic or natural), thick beard, or other factors that interfere with the face mask seal.
Contraindications to Laryngeal Mask Airway
Absolute contraindications
There is no medical contraindication to providing
ventilatory support to a patient; however, a legal contraindication
(do-not-resuscitate order or specific advance directive) may be in force
Maximum mouth opening between incisors < 2 cm (nasotracheal intubation or a surgical airway would be indicated in this case) Impassable upper airway obstruction (surgical airway would be indicated in this case).
Relative contraindications
Consciousness or presence of a gag reflex (patients
should be unconscious or receive drugs to aid intubation, such as a sedative
and a paralytic agent, prior to LMA insertion).
Increased risk of regurgitation: Prolonged prior BVM
ventilation, obesity, pregnancy > 10 weeks, patients who have not fasted or
have upper gastrointestinal issues (eg, previous surgery, bleeding, hiatal
hernia, gastroesophageal reflux disease, peptic ulcer disease). In emergencies,
use of an LMA can proceed even with these relative contraindications.
Need for high pressure ventilation (the tighter seal of an endotracheal tube or a special LMA designed to form a tighter seal is needed for patients with excessive airflow resistance in the infraglottic airways or lungs).
Complications of Laryngeal Mask Airway
Complications include
Vomiting and aspiration.
Tongue edema due to prolonged placement or balloon
overinflation .
Dental or oropharyngeal soft tissue trauma during
insertion .
Additional Considerations for Laryngeal Mask Airway.
The inflatable cuff around the rim of the mask forms a
low-pressure seal around the laryngeal inlet that allows positive pressure
ventilation.
Use low-pressure ventilation with a LMA to prevent air
from escaping the low-pressure seal and causing gastric insufflation.
If the seal is inadequate, lower the cuff pressure
somewhat. If this approach does not work, a larger mask size should be tried.
Overinflation of the cuff will make a poor seal worse.
LMAs do not protect the airway from aspiration. However, some types of LMA feature improved laryngeal seals as well as ports for insertion of gastric decompression tubes.
Relevant Anatomy for Laryngeal Mask Airway
Aligning the ear with the sternal notch may help open the
upper airway and establishes the best position to view the airway if
endotracheal intubation becomes necessary.
The degree of head elevation that best aligns the ear and sternal notch varies (eg, none in children with large occiputs, a large degree in obese patients).
Positioning for Laryngeal Mask Airway
Optimal patient position for LMA insertion is the
sniffing position.
The operator may stand at the head off the stretcher.
An assistant may stand at the side.
The sniffing position is used only in the absence of cervical spine injury:
Position the patient supine on the stretcher.
Place folded towels or other materials under the head, neck, and shoulders, flexing the neck so as to elevate the head until the external auditory meatus lies in the same horizontal plane as the sternal notch. Then tilt the head so that the face aligns on a parallel horizontal plane; this second plane will be above the first. In obese patients, many folded towels or a commercial ramp device may be needed to sufficiently elevate the shoulders and neck (see figure head and neck positioning to open the airway).
Head and neck positioning to open the airway: Sniffing
position
A: The head is flat on the stretcher; the airway is
constricted.
B: The ear and sternal notch are aligned, with the face
parallel to the ceiling (in the sniffing position), opening the
airway. Adapted from Levitan RM, Kinkle W
C: The Airway Cam Pocket
Guide to Intubation, ed. 2. Wayne (PA), Airway Cam
Technologies, 2007.
![]() 1-Position the patient supine or at a slight incline on
the stretcher. 2-Avoid moving the neck and use only the jaw thrust maneuver or chin lift without head tilt to manually facilitate opening of the upper airway LMAs that are anatomically contoured can be inserted without any neck 3-manipulation or need for finger insertion into the mouth. They may cause posterior pressure on the cervical spine; however, they are generally considered safe for patients with unstable cervical spine injury. 4-Do
not allow a patient to awaken during insertion or ventilation with a
supraglottic or endotracheal airway. If necessary, prevent the patient
from waking up or gagging (using repeated succinylcholine doses or a long-acting
paralytic) or remove or change the airway as clinically indicated. 5-Select
the appropriately sized LMA and note the maximum cuff inflation volume. 6-The
size and maximum inflation volume are usually printed on the side of the tube. Generally, size #4 is suitable for adults weighing 50
to70 kg and size #5 is suitable for adults weighing 70 to 100 kg. 7-Inflate
and deflate the cuff to check its volume and ensure that there are no leaks. With the cuff completely deflated, apply a small amount
of sterile, water-soluble lubricant to the posterior surface of the distal mask and cuff. 8-Pre-oxygenate
the patient with bag-valve-mask ventilation if possible. 9- Flex
the patient’s neck and lift the chin, and maintain manual counter-pressure on
the occiput as needed when you insert the tube. 10- Insert the tube into the mouth so that the mask opening facing anteriorly. The standard approach is to manually guide the mask along the palates and into the throat by pushing with an index (or long) finger (or thumb) placed in the v-shaped notch where the tube attaches to the mask. Push the tube cephalad, such that . 11- lubricated posterior surface of the mask follows the curve of the hard and soft palates. The mask should enter the hypopharynx along the posterior wall, to avoid deflecting and possibly causing a tube obstruction by the epiglottis. At the proper distance of insertion (as confirmed by markings on the tube), the mask will overlie the laryngeal opening, and the tip of the mask will meet (at the esophageal opening) definitive resistance to further insertion (see figure Laryngeal mask airway). 12- Release
your hand from the tube before inflating the cuff. 13-Inflate the cuff. Use half the recommended maximum cuff volume. As the mask seats over the glottic area, the tube will protrude 1 to 2 cm out of the mouth. 14- Connect
a bag-valve apparatus to the tube. 15-Begin
ventilation (8 to 10 breaths/minute, each about 500 mL and lasting about 1 second). 16- Assess
lung ventilation by auscultation and chest rise. 17- Check
end-tidal carbon dioxide to confirm placement. 18- Fix
the tube in place as appropriate. ![]() The LMA is a tube with an inflatable cuff that is inserted into the oropharynx. A: The deflated cuff is inserted into the mouth. B: With the index finger, the cuff is guided into place above the larynx. C: Once in place, the cuff is inflated. Some newer cuffs use a gel that molds to the airway rather than an inflatable cuff. Tips and Tricks for Laryngeal Mask AirwayTo improve difficult or inadequate LMA ventilation: Adjust the cuff volume. Try both lower and higher volumes (a poor cuff seal may be caused by either too low or too high cuff volumes). Adjust patient positioning while doing bag-valve ventilation to help make ventilation easier. Try a better configured sniffing position, a chin-to chest position, jaw thrust, or chin-lift maneuvers. Do the up-down
maneuver. Withdraw the LMA 5 to 6 cm, without deflating the cuff, and then
reinsert it to release an epiglottis trapped under the cuff or inside the mask. Rotate the LMA
deeper into the hypopharynx and elevate the handle toward the ceiling. Deflate the cuff and
remove the LMA. Then do another LMA insertion, using either the same LMA or one
of a larger size. Consider using
another airway, such as an intubating laryngeal mask airway, King laryngeal
tube, endotracheal intubation, or a surgical airway.
|